with sensor connection
for covers JUNG HOME ref.-no.: BT .. 1791 ..
for covers LB Management ref.-no.: .. 1790 D ..
for covers KNX RF ref.-no.: .. 1091 1ST RF .., .. 1092 1ST RF ..
Intended use- Switching of electric underfloor heating systems and electrothermal valve drives
- Operation with suitable cover
- Installation in flush box with dimensions according to DIN 49073
Product characteristics- Pulse width modulation (PWM) or two-point control (on/off)
- External temperature sensor (ref.-no.: FF NTC) can be connected
- External temperature sensors from various manufacturers can be connected (from version V03)
- Input for switching to cooling mode
- Interrupts the heating process after 60 minutes (overheating protection of a heater)
Accessories:external sensor ref.-no.: FF NTC